Advanced User Manual
www.rovingnetworks.com
rn-bluetooth-um Version 4.77 11/21/2009
809 University Avenue Los Gatos, CA 95032 Tel (408) 395-6539 info@RovingNetworks.com
~ 30 ~
ACTION COMMANDS
+ - Toggle local echo of RX chars in command mode.
C - Connect immediate to stored remote address.
C,<address> - Connect to address.
CF<address> - Connect Fast mode to address.
CFR - Connect Fast mode to stored remote address.
CT<address>,<timer> - Connect, required address, optional disconnect timer in ¼ seconds.
F,1 - Enter Fast data mode, end configuration immediate.
L - Toggle link quality readings.
I,<time>,<cod> - Device Scan Inquiry, time in seconds, optional cod = class of device filter, 0=all
IN<time>,<cod> - Device Scan Inquiry, returns NAMEs.
IS<time> - Device Scan Inquiry, fixed cod=0x001F00 to find Roving devices.
IR<time> - Device Scan Inquiry, fixed cod =0x0055AA to find instant cable pairs.
K, - Kill (disconnect) from current connection
Q - Turn off Discovery and Connectability
R,1 - Reboot
T,<0,1> - Pass receive data (from uart or BT) while in command mode.
U,<rate>,<E,O,N> - Temp Uart Change
& - return the value of the DIP Switches
W - Re-enable Discovery and Connectability.
Z - Enter low power Sleep mode